Fiber Optic Oxygen Meter for Measurements in Normal Oxygen Range

Fibox 3

The Fibox 3 is a proven fiber optic meter for precise oxygen measurements. Due to its small outer dimensions it can easily be set up. Connected to a 2 mm polymer optical fiber this oxygen meter can be applied with various oxygen sensors of type PSt3 (detection limit 15 ppb, 0 – 100 % oxygen). Fibox 3 is a temperature compensated system and delivered with a precision temperature sensor. This way most precise oxygen measurements in environments with changing temperature can be taken. The oxygen meter can be connected to a PC via USB or RS232 interface and is operated with the included software, which allows easy measurement control and data collection. Additionally, the Fibox 3 has dual 12 bit analog outputs, and an external trigger input to be connected to a data logger.

Successor OXY-1 SMA

  • For use with non-invasive optical oxygen sensors & sensor probes
  • One calibration for a multitude of sensor spots
  • Oxygen meter with included software 

Technical

Specifications
Oxygen sensorPSt3 (optical SMA connector)
Temperature sensor1 x Pt1000 temperature connector (sensor included)
Temperature performancefrom 0 °C to + 50 °C, resolution ± 0.1 °C, accuracy ± 1.0 °C
Power supply18 VDC / 5 W (110 - 240 VAC, 50 /60 Hz, adapter included)
Temperature: operating / storagefrom 0 °C to + 50 °C / from - 10 °C to + 60 °C
Relative humidityup to 80 % (non condensing)
Dimensions210 mm x 120 mm x 50 mm
Weight0.65 kg
Digital interfaceRS232 interface (RJ 11 4/4 to DSub, cable included)
USB interface (RJ 11 4/4 to USB type A, transmitter adapted cable included)
External triggerTTL compatible with galvanic isolation (BNC connector)
Analogue output specificationsDual outputs, 0 - 4095 mV, resolution 12 bit, accuracy ± 10 mV (BNC connector)
10 mV represent
Oxygen1 % air saturation
Temperature1 °C
Phase0.25 °

Related products

Oxygen sensor spots for non-invasive measurements

Oxygen Sensor Spot SP-PSt3-YAU

Sensor spots are the most versatile version of non-invasive...

More
Oxygen sensor spots for non-invasive measurements

Oxygen Sensor Spot SP-PSt3-NAU

Sensor spots are the most versatile version of non-invasive...

More
Oxygen Flow-Through Cell FTC-PSt3

O2 Flow-Through Cell FTC-PSt3

Miniaturized chemical optical oxygen sensors integrated in...

More
Autoclavable oxygen Flow-Through Cell with polymer optical fiber FTC-PSt3-YAU

Autoclavable O2 Flow-Through Cell FTC-PSt3-YAU

The FTC-PSt3-YAU is a miniaturized chemical optical oxygen...

More
Single-use oxygen Flow-Through Cell FTC-SU-PSt3

Single-Use O2 Flow-Through Cell FTC-SU-PSt3-S

Miniaturized chemical optical oxygen sensors integrated in...

More
FTM-PSt3 Oxygen Probe Integrated in Metal Flow-Through Connector

Oxygen Probe Integrated in Metal Flow-Through Connector FTM-PSt3

An oxygen exchange window is integrated in a metal...

More
DP-PSt3 Oxygen Dipping Probe

Oxygen Dipping Probe DP-PSt3

The oxygen dipping probe type PSt3 for measurement in normal...

More
OIM-PSt3 Oxygen Probe for In-Line Measurement

Oxygen Probe for In-Line Measurement OIM-PSt3

The oxygen probe for in-line measurement (OIM) consists of a...

More
OIM-PSt6-Var Trace Oxygen Probe integrated in Varivent Valve

Oxygen Probe Integrated in Varivent Valve OIM-PSt6-Var

An Oxygen Exchange Window (OEW) is integrated in a Varivent...

More
Polymer Optical Fiber POF with two SMA sockets

Polymer Optical Fiber POF

A polymer optical fiber (POF) is needed to transfer...

More
LP1 Control Panel

LP1 Control Panel

The LP-1 control panel has an LCD display which allows to...

More

Resources

Publications

Effect of Oxygen Depletion on GDH ActivityAdvanced Respirometry with Chemical Optical Sensor SpotsStudying Microbial Iron and Manganese Oxidation in Different Experimental Set-UpsOnline in Situ Measurements of Soil CO2 Concentrations in Dependence of Ash Roots (Fraxinus excelsior L.)Perfusion Culture of Cell-seeded 3D Scaffolds for Tissue EngineeringIntegration of a PreSens Oxygen Sensor Spot Into a Solid Mini BioreactorTranscriptome-Stable Isotope Probing Provides Targeted Functional and Taxonomic Insights Into Microaerobic Pollutant-Degrading Aquifer MicrobiotaStable isotope probing for hypoxic toluene degradation at the Siklós aquifer reveals prominent role of RhodocyclaceaeOxic Fe(III) reduction could have generated Fe(II) in the photic zone of Precambrian seawaterProduction of a recombinant phospholipase A2 in Escherichia coli using resonant acoustic mixing that improves oxygen transfer in shake flasksUniform tissues engineered by seeding and culturing cells in 3D scaffolds under perfusion at defined oxygen tensionsEffect of exposure to sunlight and phosphorus-limitation on bacterial degradation of coloured dissolved organic matter (CDOM) in freshwaterEffects of Iron on Chemical Sulfide Oxidation in Wastewater from Sewer NetworksAdult neural stem cells express glucose transporters GLUT1 and GLUT3 and regulate GLUT3 expressionEffects of stretch on work and efficiency of frog (Rana pipiens) muscleAerated subsurface irrigation water gives growth and yield benefits to zucchini, vegetable soybean and cotton in heavy clay soilsNew and Fast Method To Quantify Respiration Rates of Bacterial and Plankton Communities in Freshwater Ecosystems by Using Optical Oxygen Sensor SpotsOxygen consumption of a single embryo/planula in the reef-building coral Acropora intermediaROS generation in endothelial hypoxia and reoxygenation stimulates kinase signaling and kinase-dependent neutrophil recruitmentHigh cell density cultivation of recombinant yeasts and bacteria under non-pressurized and pressurized conditions in stirred tank bioreactorsFunctional Coexpression of the Mitochondrial Alternative Oxidase and Uncoupling Protein Underlies Thermoregulation in the Thermogenic Florets of Skunk Cabbage 1[W][OA]Chlorobenzene biodegradation under consecutive aerobic-anaerobic conditionsComputational evaluation of oxygen and shear stress distributions in 3D perfusion culture systems: Macro-scale and micro-structured modelsEssential fatty acids influence metabolic rate and tolerance of hypoxia in Dover sole (Solea solea) larvae and juvenilesEvaluation of a lifetime-based optode to measure oxygen in aquatic systemsA promising environmentally-friendly manganese-based catalyst for alkyd emulsion coatingsThe impact of cemented layers and hardpans on oxygen diffusivity in mining waste heaps A field study of the Halsbrücke lead-zinc mine tailings (Germany)A Novel Method to Determine Oxidation Rates of Heritage Materials in Vitro and in SituMagnitude and regulation of bacterioplankton respiratory quotient across feshwater environmental gradientsOn-line monitoring of oxygen as a non-destructive method to quantify cells in engineered 3D tissue constructsDelineation of the Key Aspects in the Regulation of Epithelial Monolayer FormationExperimental Sensitivity Analysis of Oxygen Transfer in the Capillary FringeOxygen Transfer in a Fluctuating Capillary Fringe: Impact of Microbial Respiratory ActivityMetabolic rates of a hypogean and an epigean species of copepod in an alluvial aquiferComparison of an Electrochemical and Luminescence-Based Oxygen Measuring System for Use in the Biodegradability Testing According to Closed Bottle Test (OECD 301D)Shaken flasks by resonant acoustic mixing versus orbital mixing: Mass transfer coefficient kLa characterization and Escherichia coli cultures comparison

Presens TV

Watch tutorials, webinars and informative videos about PreSens optical sensor systems.