Watch tutorials, webinars and informative videos about PreSens optical sensor systems.
Replacement Trace Oxygen Sensor for OIMs or OXYPro® TR / TRM
Oxygen Exchange Cap OEC-PSt6-YAU
The Oxygen Exchange Cap with integrated sensor type PSt6 is made of stainless steel. The sensor has a maximum measurement range of 0 - 10 % oxygen, with a detection limit of 0.002 % O2. The OEC-PSt6-YAU is available in different versions: YOP for bioprocess monitoring, safe for food applications (CAF), or with a hydrophobic Teflon coating (PTFE) for measurements in aggressive environments. It can be screwed to the top of an OIM (Oxygen Probe for In-line Measurements) or the OXYPro® TR / TRM. This way a used sensor can easily be exchanged as the cap can be calibrated with one fast barcode scan. OEC-PSt6-YAU stands cleaning in place & steam sterilization.
- Maximum measurement range of 0 - 10 % O2
- Different versions: food applications, aggressive environments
- Stands SIP (max. + 140 °C, 1.5 atm) & CIP (+ 80 °C, 2 % NaOH)
- Easy exchange due to barcode calibration
- Pressure resistant
Applications
Process Control in Biotech & Pharma
The OIMs, the oxygen probes for in-line measurement, are designed for harsh measurement conditions. These systems give high accuracy and are almost maintenance-free as they do not contain any membranes and electrolytes. The sensors are fully autoclavable and sterilizable (CIP & SIP).
In-line Oxygen Measurement in Brewing and Beverage Industry
Even low concentrations of oxygen influence shelf-life and the taste of certain beverages. Due to the extraordinary low detection limit and outstanding accuracy of PreSens trace oxygen sensors, the quality of oxygen-sensitive products such as beer, wine and soft drinks is secured.
The optical sensors have – compared to standard electrodes – a very fast response time and they are very easy to maintain.
Technical
Specifications | OEC-PSt6-YAU-YOP | OEC-PSt6-YAU-CAF | OEC-PSt6-YAU-PTFE |
---|---|---|---|
*at 20 °C, 960 - 980 hPa; humidified gas mixture **after customized calibration ***determined changing from 10 % oxygen gas to nitrogen 5.0 ****determined changing from air-saturated water to a freshly prepared 1 % sodium sulfite solution | |||
Measurement range* | Optimal: 0 - 5 % O2, 0 - 50 hPa, 0 - 2.0 mg/L Max.**: 0 - 10 % O2, 0 - 100 hPa, 0 - 4.5 mg/L | ||
Limit of detection* | 0.002 % O2, 0.02 hPa, 1 ppb | ||
Resolution* | 0.002 % O2 ± 0.0006 % O2, 0.046 % O2 ± 0.0008 % O2, 0.2 % O2 ± 0.001 % O2 1 ppb ± 0.3 ppb, 20 ppb ± 0.4 ppb, 100 ppb ± 0.5 ppb | ||
Response time (t90) Gaseous O2*** Dissolved O2**** | < 10 sec. < 30 sec. | < 15 sec. < 40 sec. | < 85 sec. < 100 sec. |
Properties | |||
Compatibility | Aqueous solutions | ||
No cross-sensitivity to | pH 1 - 14, CO2, SO2, ionic species | ||
Cross-sensitivity to | Chlorine gas Organic solvents such as pure acetone, toluene, chloroform or methylene chloride | ||
Steam sterilization (max. + 140 °C, 1.5 atm) | Yes | Yes | Yes |
Cleaning in Place (CIP) (+ 80 °C, 2 % NaOH) | Yes | Yes | Yes |
Cleaning Procedure | 3 % H2O2, acidic agents (HCl, H2SO4) max. 4 - 5 % Ethanol, methanol, cleaning agents at room temperature | ||
Calibration | Two-point calibration in oxygen-free environment (e. g. nitrogen 5.0, 1 % sodium sulfite solution) and a second calibration medium between 1 and 2 % oxygen | ||
Storage stability | 5 years provided the sensor material is stored at room temperature in dry conditions and in the dark | ||
Pressure resistance* | - 1 bar to + 12 bar | ||
Temperature range operation | Optimal: 0 °C to + 50 °C Max.: - 10 °C to + 90 °C | ||
Storage conditions | Optimal: room temperature (+ 20 °C ± 5 °C) Max.: 0 °C to + 70 °C, 80 % rel. humidity | ||
Variants | - | Safe for food applications | Hydrophobic Teflon coating |