Easy Integration into Transparent Vessels for Online Oxygen Monitoring

Self-adhesive Oxygen Sensor Spot SP-PSt3-SA

With the new self-adhesive technology it is easy to integrate these sensor spots in nearly any transparent glass or plastic vessel. The oxygen is measured contactless and non-destructively from the outside – through the vessel wall. The SP-PSt3-SA has a measurement range of 0 – 100 % oxygen in dissolved or gaseous phase and can therefore be used for measurements in liquids as well as in headspace. These sensor spots are extremely versatile and can be applied from biotechnological applications up to quality checks for packed or bottled products.

  • Simplified integration with new self-adhesive technology
  • Compatible with glass & nearly all plastic vessels
  • Pre-calibrated & ready-to-use
  • Online monitoring without sampling
  • Non-invasive measurements through the vessel wall
Get a quote Place an order

Technical

Specifications Gaseous & Dissolved O2 Dissolved O2
*after two-point calibration as described in the manual
Measurement range

0 – 100 % O2

0 – 1000 hPa

0 – 45 mg/L

0 – 1400 µmol/L
Limit of detection 0.03 % oxygen 15 ppb
Resolution

± 0.01 % O2 at 0.21 % O2
± 0.1 % O2 at 20.9 % O2
±0.1 hPa at 2 hPa

± 1 hPa at 207 hPa

± 0.004 mg/L at 0.091 mg/L
± 0.04 mg/L at 9.1 mg/L
± 0.14 µmol/L at 2.83 µmol/L

± 1.4 µmol/L at 283.1 µmol/L
Accuracy* ± 0.4 % O2 at 20.9 % O2
± 0.05 % O2 at 0.2 % O2
 
Drift < 0.03 % O2 within 30 days (sampling interval of 1 min. / at 0% oxygen)
Measurement temperature range from 0 to + 50 °C
Response time (t90) < 6 sec. < 40 sec.
Properties    
Compatibility Aqueous solutions, methanol
No cross-sensitivity

pH 1 – 14
CO2, H2S, SO2
Ionic species

Cross-sensitivity Organic solvents, such as acetone, toluene, chloroform or methylene chloride
Chlorine gas
Sterilization procedure Ethylene oxide (EtO)
Gamma irradiation
Cleaning procedure Aqueous solutions
Do not expose to ethanol!
Calibration Two-point calibration with oxygen-free environment (nitrogen, sodium sulfite) and air-saturated environment
Storage stability 24 months provided the sensor material is stored in the dark

Related products

Fibox 4 Stand-alone Fiber Optic Oxygen Meter

Fibox 4

The battery powered Fibox 4 is designed for easy handheld…

More
Fibox 4 trace handheld fiber optic O2 meter

Fibox 4 trace

The Fibox 4 trace is a stand-alone oxygen meter designed for…

More
OXY-1 SMA compact optical O2 meter

OXY-1 SMA

Due to its small outer dimensions OXY-1 SMA can be set up…

More
OXY-4 SMA 4-channel optical O2 meter

OXY-4 SMA (G3)

This multi-channel oxygen meter is ideally suited for…

More
OXY-1 SMA trace Small Optical Trace Oxygen Meter

OXY-1 SMA trace

As a successor of our established Fibox 3 trace, the OXY-1…

More
OXY-4 SMA trace (G3) Multi-Channel Trace Oxygen Meter

OXY-4 SMA trace (G3)

The OXY-4 SMA trace is compatible with sensor spots, dipping…

More
Fibox 3 Fiber Optic Oxygen Meter

Fibox 3

The Fibox 3 is a proven fiber optic meter for precise oxygen…

More
Fibox 3 trace Fiber Optic Trace Oxygen Meter

Fibox 3 trace

The Fibox 3 trace is a proven fiber optic device for precise…

More
Polymer Optical Fiber POF with two SMA sockets

Polymer Optical Fiber POF

A polymer optical fiber (POF) is needed to transfer…

More
SOA Stick-On Adapter for Polymer Optical Fibers

Stick-On Adapter SOA

The stick-on adapter is used to attach the polymer optical…

More
Adjustable Velcro®-type Adapter for Round Containers (ARC) with SMA sockets

Adapter for Round Containers ARC

The Adapter for Round Containers is an adjustable…

More
Integration Set for Sensor Spots IS-SP with suction pump

Integration Set for Sensor Spots IS-SP

The integration set is a suction pump that comes with…

More
Coaster for Shake Flasks CFG with Polymer Optical Fiber for optical sensor read-out

Coaster for Shake Flasks CFG

The coaster CFG is placed underneath the shake flask with…

More

Resources

FAQs

Can the customer integrate the optical sensor spots by himself / herself? Do I have to mount the sensors in the dark because it says "Protect from light" on the packing? Do the sensors work in turbid solutions? How can I convert an oxygen value into a different oxygen unit? How can I prepare the calibration solutions cal0 and cal100 for oxygen sensors? How do I import data into excel from a text file containing measurement data? How do I verify whether the oxygen sensor is giving correct readings (performance proof)? How does an oxygen sensor work? How does salinity affect the oxygen measurement? How does temperature affect the oxygen measurement? How many samples should I use to perform a batch calibration? In which vessel can I integrate a sensor spot? Is the glue or the sensor spot biocompatible - which tests were done? Are there any studies on leachables and extractables? Is there a standard recommended distance to place the polymer optical fiber (POF) from the sensor spot? The Stern-Volmer-equation What are the response times for the oxygen sensors based on the 2 mm fiber like non-invasive oxygen sensors and oxygen probes? What does -YAU, -NAU or -SA stand for in the oxygen sensor spot names and what is the difference between those sensor types? What factors will affect the oxygen reading? What is the time of delivery? Where do I need sensor spot sizes different from the common diameter of 5 mm (approx. 0.2 inch)? Which glue can I use to integrate optical sensor spots? Which substances can interfere with the optical O2, pH and CO2 measurements?

Software

×

Presens TV

Watch tutorials, webinars and informative videos about PreSens optical sensor systems.

All videos