Top

Online Dissolved Oxygen Monitoring in Disposable Bioreactors

DO Nice Port

This port with integrated oxygen sensor is for customized application in flexible, bag-type bioreactors like storage and mixing bags. It is mainly designed for cell culture applications but can also be used for monitoring microbial fermentation. The port is made of polyethylene which allows easy welding with the bags. A polymer optical fiber is attached to the port from the outside to read out the sensor. The Nice Port DO enables contactless measurements in culture bags, so there is no risk of contamination.

  • Online dissolved O2 monitoring in single-use bioreactors
  • Non-invasive measurements, no risk of contamination
  • Easy integration by welding
  • Pre-calibrated sensor
Get a quote Place an order

Applications

Pharma Industry: Oxygen Monitoring in Bags

Bags and single-use bioreactors are in the process of revolutionizing the way biopharmaceuticals are manufactured. Our non-invasive oxygen sensors are the tools to make the cultivation vessels fully disposable. As non-invasive pH sensors are also available, the two key parameters oxygen and pH can be controlled online.


Technical

Specifications Dissolved O2
*after two-point calibration as described in the manual
Measurement range

0 – 500 % air saturation

0 – 1400 µmol/L
Limit of detection 15 ppb
Resolution

± 0.05 % air saturation at 1 % air saturation
± 0.5 % air saturation at 100 % air saturation
± 0.14 µmol/L at 2.83 µmol/L

± 1.4 µmol/L at 283.1 µmol/L
Accuracy* ± 0.4 % O2 at 20.9 % O2
± 0.05 % O2 at 0.2 % O2
 
Drift < 0.03 % O2 within 30 days (sampling interval of 1 min. / at 0 % oxygen)
Measurement temperature range from 0 to + 50 °C
Response time (t90) < 6 sec.
Properties    
Compatibility Aqueous solutions, ethanol, methanol
No cross-sensitivity

pH 1 – 14
CO2, H2S, SO2
Ionic species

Cross-sensitivity Organic solvents, such as acetone, toluene, chloroform or methylene chloride
Chlorine gas
Sterilization procedure Ethylene oxide (EtO)
Gamma irradiation
Cleaning procedure 3 % H2O2
Acidic agents (HCl, H2SO4), max. 4 – 5 %
Calibration Two-point calibration with oxygen-free environment (nitrogen, sodium sulfite) and air-saturated environment
Storage stability 24 months provided the sensor material is stored in the dark

Related products

Electro-optical O2 modules for customized integration

Electro-Optical Module EOM-O2-mini

The electro-optical module EOM-O2-mini is a precise OEM…

More
Fibox 4 Stand-alone Fiber Optic Oxygen Meter

Fibox 4

The battery powered Fibox 4 is designed for easy handheld…

More
Fibox 4 trace handheld fiber optic O2 meter

Fibox 4 trace

The Fibox 4 trace is a stand-alone oxygen meter designed for…

More
OXY-1 SMA compact optical O2 meter

OXY-1 SMA

Due to its small outer dimensions OXY-1 SMA can be set up…

More
OXY-1 SMA trace Small Optical Trace Oxygen Meter

OXY-1 SMA trace

As a successor of our established Fibox 3 trace, the OXY-1…

More
OXY-4 SMA 4-channel optical O2 meter

OXY-4 SMA (G3)

This multi-channel oxygen meter is ideally suited for…

More
OXY-4 SMA trace (G3) Multi-Channel Trace Oxygen Meter

OXY-4 SMA trace (G3)

The OXY-4 SMA trace is compatible with sensor spots, dipping…

More
Polymer Optical Fiber POF with two SMA sockets

Polymer Optical Fiber POF

A polymer optical fiber (POF) is needed to transfer…

More
Fibox 3 Fiber Optic Oxygen Meter

Fibox 3

The Fibox 3 is a proven fiber optic meter for precise oxygen…

More
Fibox 3 trace Fiber Optic Trace Oxygen Meter

Fibox 3 trace

The Fibox 3 trace is a proven fiber optic device for precise…

More
×

Knowledge

Select by industry

Presens TV

Watch tutorials, webinars and informative videos about PreSens optical sensor systems.

All videos