Simultaneous Oxygen and pH Monitoring in Multidishes
OxoHydroDish OHD6
These 6-well multidishes have an oxygen and pH sensor integrated at the bottom of each well. They are delivered irradiated and pre-calibrated and are therefore ready-to-use. These SensorDishes® are read out with the SDR, which shows either the measured oxygen or pH values online, while the other parameter values are stored and can be analysed after data export.
- Ready-to-use
- Pre-calibrated
- Manual calibration possible
- Ideal for cell cultivation & tissue engineering
Technical
Specifications | pH | Dissolved Oxygen |
---|---|---|
* at 37 °C in physiological solutions | ||
Measurement range | 6.0 - 8.5 | 0 - 50 % O2 |
Resolution* | ± 0.05 pH at pH = 7 | ± 0.4 % O2 at 20.9 % O2 |
Precision* | ± 0.2 pH at pH = 7 (Sensor batch calibration) ± 0.1 pH at pH = 7 (Sensor spot calibration) | ± 1 % O2 at 20.9 % O2 |
Drift* | < 0.1 pH within one week (sampling interval 10 min.) | < 0.2 % O2 within one week (sampling interval 10 min.) |
Measurement temperature range | from + 15 to + 45 °C | from + 15 to + 45 °C |
Response time* (t90) | at 25 °C: < 120 sec. | at 25 °C: < 30 sec. |
Properties | ||
Compatibility | Aqueous solutions, ethanol (max. 10 % v/v), methanol (max. 10 % v/v), pH 2 - 10 | |
Cross-sensitivity | Reduced to ionic strength (salinity); high concentration of small fluorescent molecules in the visible range can interfere | |
Maximum filling volume | 15 mL | |
Calibration | Pre-calibrated Disposables are delivered beta-irradiated |
Related products
Resources
FAQs
Can I re-use the SensorDishes®?
Can I use the SDR with other formats than the 24-well plates?
Do cells grow on the sensor inside the SensorDishes®?
Do SensorDishes® come sterile?
How do I import data into excel from a text file containing measurement data?
How long can I use a SensorDish®?
How long do I need to equilibrate before starting a SDR measurement?
I use the OxoHydroDish (OHD6) with the SDR. How do I see the values of both parameters (oxygen and pH) with the SDR software?
The SDR software shows "no sensor" instead of a value. What is the reason?
What is the time of delivery?
Which substances can interfere with the optical O2, pH and CO2 measurements?
Which toxicity tests where done with the SensorDish®?
Why are there two different calibration data sets for SensorDishes®?
Why do I need to equilibrate my samples for such long time periods before measurement with the SDR?
Why do I see peaks in the graphs of the SDR software (especially in the oxygen signal) when I open the incubator door / take the plates out of the incubator?
Why does the SDR software show pH<5, although I know that my sample is basic?