Top

Online Monitoring in Perfusion Systems with Single-use Sensor

Single-Use pH Flow-Through Cell FTC-SU-HP5-S

A miniaturized optical pH sensor is attached to a color coded stick, which can be attached to flow-through cells of different size and shape, according to requirements. A polymer optical fiber connects the sensor inside the flow-through cell to the pH meter. The single-use T-cell of the FTC-SU-HP5-S is made of polycarbonate and all parts come beta-irradiated.

  • Single-use flow-through cell
  • Precise online monitoring of pH in perfusion systems
  • Different sizes and shapes for various flow rates
  • Easy connection to external tubing
  • Customized connectors are available, e. g. CPC
Get a quote Place an order

Applications

pH Monitoring in Liver Cell Bioreactor

An important aspect of efficient liver cell bioreactors is the automated regulation of physio-chemical culture parameters. A non-invasive pH regulation device for a perfusion bioreactor has been developed. The high performance of the system is based on one of our chemical optical flow-through cells for pH detection and its combination with precision mass-flow controllers for gas. The new controller allows long time stable and contamination free online pH regulation in complex bioreactor systems - an important technical contribution for future clinical applications.

Application Note by Marco Decker: pH Regulation for a Liver Cell Bioreactor


Online Measurement in Perfusion Systems

Beta-irradiated and pre-calibrated pH and DO flow-through sensors can be integrated into perfusion systems. This allows easy control of process parameters in perfusion reactors. Typically Luer connectors are used, though different sizes for larger or smaller flow rates are available.


Technical

Specifications*
Measurement range 5.5 - 8.5 pH
Resolution at pH = 7: ± 0.01 pH
Accuracy** at pH = 7: ± 0.05 pH sensor spot calibration
at pH = 7: ± 0.10 pH sensor batch calibration
Drift at pH = 7: < 0.005 pH per day (sampling interval of 1 min.)
Measurement temperature range from + 5 to + 50 °C
Response time (t90)** < 120 sec.
Properties*
Compatibility Aqueous solutions, ethanol (max. 10 % v/v), methanol (max. 10 % v/v), pH 2- 10
Cross-sensitivity Reduced to ionic strength (salinity); a high concentration of small fluorescent molecules in the visible range can interfere
Cleaning procedure*** Irradiation, Ethylene oxide (EtO)
Calibration FTCs are pre-calibrated; single-point calibration is recommended
T-cell formats Luer T-cell (delivered), inner diameter 5 mm, cell volume 0.3 mL;
1/4" x 1/4" (Qosina), cell volume 2.1 mL;
3/8" x 3/8" (Qosina), cell volume 4.6 mL;
1/2" x 1/2" (Qosina), cell volume 8.3 mL

* provided pH sensors are used without further handling in physiological solutions
** calibration and following measurements in the same conditions / system; equilibrated FTC with physiological solution and sufficient flow rate (min. 15 mL/min) at 37 °C
***recalibration may be required

Related products

pH-1 SMA HP5 Compact Fiber Optic pH Meter

pH-1 SMA HP5

Due to its small outer dimensions pH-1 SMA HP5 can be set up…

More
Polymer Optical Fiber POF with two SMA sockets

Polymer Optical Fiber POF

A polymer optical fiber (POF) is needed to transfer…

More
Fiber optic pH meter pH-1 mini

pH-1 mini

The pH-1 mini is a precise fiber optic pH meter. It is used…

More
Electro-Optical Module EOM-pH-mini OEM Component  For Contactless Measurements with pH Sensor Spots

Electro-Optical Module EOM-pH-mini

The electro-optical module EOM-pH-mini is a precise OEM…

More
×

Presens TV

Watch tutorials, webinars and informative videos about PreSens optical sensor systems.

All videos