Top

Bare Fiber Oxygen Microsensor with a Tip Size Thinner than a Hair

Implantable Oxygen Microsensor IMP-PSt1

This miniaturized optical oxygen microsensor is designed for various customized applications. The tiny probe has a tip size < 50 µm to 140 µm while the outer diameter ranges from 140 µm to 900 µm. The microsensor tip is not mounted into any additional housing. The bare glass fiber tip can be mounted to your own housings, steel tubes and micro respirometer chambers etc. The small outer diameter even allows insertion into implantable Venflon-tubes. Moreover, the microsensor can be deployed in sealed containers to measure the oxygen content directly. The IMP-PSt1 has a measurement range of 0 – 50 % oxygen, with a limit of detection of 0.05 % O2.

  • High spatial resolution (< 50 μm)
  • High temporal resolution (t90 < 3 sec.)
  • Integration into customized housings and set-ups
  • No consumption of oxygen
  • Measurement in headspace & liquids
Get a quote Place an order

Technical

Specifications Gaseous & Dissolved O2 Dissolved O2
*after two-point calibration as described in the manual
**TS: tapered sensor tip with a diameter < 50 μm and no optical isolation
***TF: flat-broken sensor tip with a diameter of 140 μm
Measurement range

0 – 50 % O2

0 – 500 hPa

0 – 22.5 mg/L

0 – 700 µmol/L
Limit of detection 0.05 % oxygen 20 ppb
Resolution

± 0.01 % O2 at 0.21 % O2
± 0.09 % O2 at 20.9 % O2
±0.1 hPa at 2 hPa

± 1 hPa at 207 hPa

± 0.005 mg/L at 0.09 mg/L
± 0.04 mg/L at 9.06 mg/L
± 0.14 µmol/L at 2.83 µmol/L

± 1.3 µmol/L at 283 µmol/L
Accuracy* ± 0.4 % O2 at 20.9 % O2
± 0.05 % O2 at 0.2 % O2
 
Drift < 0.1 % O2 within 30 days (sampling interval of 1 min.)
Measurement temperature range from 0 to + 50 °C
Response time TS** (t90) < 1 sec. (gas) < 2 sec. (liquid)
Response time TF*** (t90) < 15 sec. (gas) < 30 sec. (liquid)
Properties    
Compatibility Aqueous solutions, ethanol, methanol
No cross-sensitivity

pH 1 – 14
CO2, H2S, SO2
Ionic species

Cross-sensitivity Organic solvents, such as acetone, toluene, chloroform or methylene chloride
Chlorine gas
Sterilization procedure

Steam sterilization
Ethylene oxide (EtO)

Cleaning procedure 3 % H2O2
Ethanol
Soap solution
Calibration Two-point calibration with oxygen-free environment (nitrogen, sodium sulfite) and air-saturated environment
Storage stability 60 months provided the sensor material is stored in the dark at room temperature

Related products

Microx TX3 Micro Fiber Optic Oxygen Meter

Microx TX3

The Microx TX3 is a precise micro fiber optic oxygen meter.…

More
Microx TX3 trace Micro Fiber Optic Oxygen Meter

Microx TX3 trace

The Microx TX3 trace is a precise micro fiber optic oxygen…

More
Multi-channel fiber optic oxygen meter OXY-4 micro

OXY-4 micro

The OXY-4 micro is a precise multi-channel micro fiber optic…

More
Multi-channel fiber optic oxygen meter OXY-10 micro

OXY-10 micro

The OXY-10 micro is a precise multi-channel oxygen meter for…

More
Manual Micromanipulator with Needle-type O2 Microsensor

Manual Micromanipulator MM

The Manual Micromanipulator MM is specifically designed for…

More
MM33 Manual Micromanipulator

Manual Micromanipulator MM33

The Manual Micromanipulator MM33 offers high resolution…

More
Automated Micromanipulator with Heavy Stand

Automated Micromanipulator AM

The Automated Micromanipulator is specifically designed for…

More
PreSens Profiling Studio Software screenshots

PreSens Profiling Studio

This software enables control of the Automated…

More

Resources

×

Knowledge

Select by industry

Presens TV

Watch tutorials, webinars and informative videos about PreSens optical sensor systems.

All videos