Multi-channel Oxygen Meter for Parallel Monitoring with Multiple Sensors

OXY-4 mini

The OXY-4 mini is a multi-channel fiber optic oxygen meter for simultaneous read-out of up to 4 oxygen sensors. It is used with sensors based on a 2 mm optical fiber. A PC is connected to run the user-friendly software. OXY-4 mini is compatible with sensors type PSt3 (detection limit 15 ppb, 0 – 100 % oxygen).

  • For use with sensor spots (contactless measurement) & sensor probes
  • One calibration for a multitude of sensor spots
  • Software included

Applications

Food & Beverage: Oxygen Permeation Measurement in PET Bottles

Non-invasive oxygen sensors measure both in liquid and in gaseous (headspace) phases. They perform through transparent materials up to a thickness of 10 mm and even through slightly opaque packaging. The measurement is carried out by firmly holding the fiber optic probe against the side of a PET bottle where the sensor spot is positioned. Adjustable mountings and bespoke fixtures are available. This system allows even the parallel measurement of different bottles as the fiber can be moved from bottle to bottle.


Long-term Measurements in Soil

PreSens offers dipping probes for oxygen measurement that does not consume oxygen. Due to their small dimensions they do not disturb the flow and mass-transport and consequently display the in-situ oxygen concentration. As minisensors from PreSens are long-term stable they can be implanted in soil for many years! With this new method the process of soil aeration, which is very critical for plant productivity, can be investigated.

Dr. Heidi Heuberger, Technical University of Munich, Munich, Germany


Technical

Specifications
Oxygen sensorPSt3 (optical SMA connector)
Power supply110 - 230 VAC, 50 / 60 Hz, max. 40 vA (cables included)
Temperature: operating / storagefrom 0 °C to + 50 °C / from - 10 °C to + 60 °C
Relative humidityup to 80 % (non condensing)
Dimensions300 mm x 250 mm x 135 mm
Weight3.3 kg
Digital interfaceRS232 interface (RJ 11 4/4 to DSub9, cable included)
USB interface (RJ 11 4/4 to USB type A, transmitter adapted cable included)

Related products

Oxygen sensor spots for non-invasive measurements

Oxygen Sensor Spot SP-PSt3-NAU

Sensor spots are the most versatile version of non-invasive…

More
Oxygen sensor spots for non-invasive measurements

Oxygen Sensor Spot SP-PSt3-YAU

Sensor spots are the most versatile version of non-invasive…

More
Oxygen Flow-Through Cell FTC-PSt3

O2 Flow-Through Cell FTC-PSt3

Miniaturized chemical optical oxygen sensors integrated in…

More
Single-use oxygen Flow-Through Cell FTC-SU-PSt3

Single-Use O2 Flow-Through Cell FTC-SU-PSt3-S

Miniaturized chemical optical oxygen sensors integrated in…

More
Autoclavable oxygen Flow-Through Cell with polymer optical fiber FTC-PSt3-YAU

Autoclavable O2 Flow-Through Cell FTC-PSt3-YAU

The FTC-PSt3-YAU is a miniaturized chemical optical oxygen…

More
DP-PSt3 Oxygen Dipping Probe

Oxygen Dipping Probe DP-PSt3

The oxygen dipping probe type PSt3 for measurement in normal…

More
OIM-PSt3 Oxygen Probe for In-Line Measurement

Oxygen Probe for In-Line Measurement OIM-PSt3

The oxygen probe for in-line measurement (OIM) consists of a…

More
OIM-PSt3-Var Oxygen Probe integrated in Varivent Valve

Oxygen Probe Integrated in Varivent Valve OIM-PSt3-Var

An optical window with oxygen sensor (Optical Exchange…

More

Resources

Publications

Simultaneous pH, CO2 and O2 Measurements in Algae Photobioreactor Monitoring Oxygen Dynamics at the Sediment-Water Interface Cell Growth and Recombinant Protein Production in Small-Scale Culture Vessels Online pH and DO Measurements in Microcarrier-Based hMSC Cultivations Studying Microbial Iron and Manganese Oxidation in Different Experimental Set-Ups Ischemia-related Cell Damage in Extracorporeal Preserved Tissue Monitoring Oxygen in Perfused Muscular Tissue Using Flow-Through Cells FTC-PSt3 Bioreactor-manufactured cartilage grafts repair acute and chronic osteochondral defects in large animal studies Hypoxia and matrix viscoelasticity sequentially regulate endothelial progenitor cluster-based vasculogenesis Contrasting habitats but comparable microbial decomposition in the benthic and hyporheic zone Production of functionalized oligo-isoprenoids by enzymatic cleavage of rubber Structural and Functional Analysis of Latex Clearing Protein (Lcp) Provides Insight into the Enzymatic Cleavage of Rubber RoxB Is a Novel Type of Rubber Oxygenase That Combines Properties of Rubber Oxygenase RoxA and Latex Clearing Protein (Lcp) Assays for the Detection of Rubber Oxygenase Activities Biomass-specific respiration rates of benthic meiofauna: Demonstrating a novel oxygen micro-respiration system Niche specialization of reef-building corals in the mesophotic zone: metabolic trade-offs between divergent Symbiodinium types Microfluidic Reactor for Continuous Cultivation of Saccharomyces cerevisiae Investigation of the Central Carbon Metabolism of Sorangium cellulosum: Metabolic Network Reconstruction and Quantification of Pathway Fluxes Design and development of microbioreactors for long-term cell culture in controlled oxygen microenvironments Online oxygen measurements in ex vivo perfused muscle tissue in a porcine model using dynamic quenching methods A System of Miniaturized Stirred Bioreactors for Parallel Continuous Cultivation of Yeast With Online Measurement of Dissolved Oxygen and Off-Gas Latex Clearing Protein (Lcp) of Streptomyces sp. Strain K30 Is a b-Type Cytochrome and Differs from Rubber Oxygenase A (RoxA) in Its Biophysical Properties Assessing viability of extracorporeal preserved muscle transplants using external field stimulation: a novel tool to improve methods prolonging bridge-to-transplantation time Monitoring bridge scour using dissolved oxygen probes Introducing two sensing schemes for bridge scour monitoring

Software

Presens TV

Watch tutorials, webinars and informative videos about PreSens optical sensor systems.

All videos