Top

24 Deep Well Plate with Integrated pH Sensors for Read-out with the SDR

Deep Well HydroDish® HD24-DW

The Deep Well HydroDish® HD24-DW is a disposable polystyrene multidish and used for shaken cultures. Pre-calibrated pH sensors are integrated at the flat bottom of each square well and are read out with the SDR SensorDish® Reader. They are delivered beta-irradiated.

  • Ready-to-use
  • For shaken cultures
  • Pre-calibrated
  • Manual calibration possible
  • For microbes & cell cultures
Get a quote Place an order

Applications

Assessing Optimal Growth Conditions for Shaken Yeast Culture

The yeast P. guillermondii was cultivated in deep well Oxo- and HydroDishes to examine growth profiles and determine the minimal filling volumes for sensor read-out at a shaking speed of 200 rpm. As no optical shielding mask (SDR-OSM24) was used in these experiments, recordings show a higher noise-ratio at lower filling volumes. Both oxygen and pH kinetics show clearly when the initial substrate is consumed and the cultures switch to metabolise another substrate. This substrate change correlates with the filling volume, as low volume samples had better oxygen supply and grew faster, so the initial substrate was used up earlier. The optimal working volume for yeast cultivation in the deep well plates is 1.25 - 1.5 mL. 

Thomas Grimm, BIOWORX, Berlin, Germany


Technical

Specifications
* in physiological solutions, 37 °C
Measurement range pH 6.0 - 8.5
Resolution* at pH = 7: ± 0.05 pH
Precision* ± 0.2 pH at pH = 7 (sensor batch calibration)
± 0.1 pH at pH = 7 (sensor spot calibration)
Drift* < 0.1 pH within one week (sampling interval 10 min.)
Measurement temperature range from + 15 to + 45 °C
Response time (t90) at 25 °C: < 120 sec.
Properties
Compatibility Aqueous solutions, ethanol (max. 10 % v/v), methanol (max. 10 % v/v), pH 2 - 10
Cross-sensitivity Reduced to ionic strength (salinity); high concentration of small fluorescent molecules in the visible range can interfere
Calibration Pre-calibrated
Disposables are delivered beta-irradiated
Maximum filling volume 10 mL

Related products

SDR SensorDish® Reader Basic Set Non-invasive Online Culture Monitoring in Multiwell Plates

SDR SensorDish® Reader Basic Set

The SDR SensorDish® Reader is a small 24-channel reader for…

More
SDR SensorDish® Reader Extension Set 24-Channel Reader for Online O2 & pH Monitoring in 6- and 24-Well Plates

SDR SensorDish® Reader Extension Set

Up to 9 SDR Extension Sets can be combined with one Basic…

More
Optical Shielding Mask SDR-OSM24

Optical Shielding Mask SDR-OSM24

The optical shielding mask is designed for use with the SDR…

More
OD24-DW 24 Deep Well Plate with integrated optical O2 Sensors

Deep Well OxoDish® OD24-DW

The Deep Well OxoDish® OD24-DW is a disposable polystyrene…

More
MicroFlask Clamp Dual for 2 PreSens SDRs

Clamp System Dual for 2 PreSens SDRs

The Clamp System Dual by Enzyscreen fastens up to 2…

More
MicroFlask Clamp for 4 PreSens SDRs

Clamp System for 4 PreSens SDRs

This Clamp System by Enzyscreen fastens up to 4 SensorDish®…

More
Sandwich Cover for 24-Well Deep Well Plates

Sandwich Cover for 24-Well Deep Well Plates

This metal cover by Enzyscreen has 24 holes and contains 3…

More

Resources

×

Presens TV

Watch tutorials, webinars and informative videos about PreSens optical sensor systems.

All videos